HD Silent Compressor
Description
Silent reaches new heights in terms of soundproofing, allowing to go below the threshold of 70 dB in operation. Built to answer needs of intensive use and when large capacities are required of reloading, it is equipped with 4 front filling attacks with high pressure hoses and an intuitive dashboard control. It is also equipped with an electric motor and powerful pumping units. For a longer life of the filters Tornado high pressure dryer is recommended. Available as an option: the Presec system for control of filter saturation or the SAM system for analysis multigas and the remote recharging panel. 4-stage high pressure pumping unit.Have a question about this product? Our friendly sales team are happy to help +44 (0)1772 687775 / [email protected]
4-stage high pressure pumping unit.
- aluminum block,
- Forged steel gooseneck
- forced lubrication on the 4th stage cylinder via gear pump
- Oil filtration
- Aluminum connecting rods
- Roller main bearings
- Roller connecting rod bearings
- 1st, 2nd and 3rd stage cylinders in special cast iron
- 4th stage cylinder in special treated steel.
- Stainless steel intake and exhaust valves
- Stainless steel interstage cooling pipes
- Separator after 2nd, 3rd and 4th stage
- Safety valves after each stage
- Oil level sensor
- Prepared for Hyperfilter filtering system
Purification at the highest level.
Placed after the last separator of the compressor and before the pressure maintenance valve, the purification system Hyperfilter enables a reliable treatment of the breathing air according to DIN EN 12021¹ when using original filter cartridges. The separator present between the 2nd and 3rd stage of the purification circuit allows to extract the greatest possible humidity. The filtering capacity with inlet air at 20°C and 200 bar is 4300 m³.
Electrical cabinet
- ON/OFF switch with motor protection switch.
- Digital electronic pressure switch which stops the compressor at the final pressure.
- Drainage of all separators between individual stages and also of the after-separator during compressor operation
- Timer for automatic condensate drain device.
- Built-in dry start (automatic drain each time the unit is switched off).
- Condensate collection tank 5 litres, with silencer; capacity of about 3 litres, for the ecological disposal of the condensate.
- Interstage pressure gauges display the operating pressure for individual compression stages. This pressure information makes it possible to check the tightness of the valves (inlet and outlet) of each stage and to quickly identify potential sources of failure.
Chassis
Silent chassis with vertical development, designed for environments that require a low noise level. The oil level and drain reported to the outside, the control console equipped with inter-stage pressure gauges, the oil pressure gauge, the internal temperature indicator, the phase presence and wrong sequence alarm, the lack alarm oil and the commands of run stop and manual drain of the condensate allow an easy management and maintenance of the compressor.
Technical data
Gas type - Breathable air (EN 12021) – Nitrox 40% max O2 – Helium – Nitrogen
Suction pressure - Atmospheric max 300 millibars
Nominal pressure - 250bar / 330bar / 360bar
Operating pressure - 250bar / 330bar / 360bar
Maximum working pressure - 420 bars
Allowed temperature range - -10°C ÷ +40°C
Altitude range allowed - 0 ÷ 1,500 m above sea level
Maximum inclination allowed - 15th
Design - Soundproof cabinet
Operating voltage, standard - 400V; 50Hz
Other operating voltage (On a three-phase electric motor at 60 Hz, the power (kW / Hp) increases by 20%.) - 230V 50Hz / 440V 60Hz / 230V 60Hz
Oil - Synthetic Coltri Oil ST 755
Oil change interval - Every year / 1,000 h
Chassis - 1.5 mm thick steel - RAL 9005 color - Powder coating - scratch resistant
Compressor
Pumping unit flow rate Measured during the filling of a 10 liter cylinder with a tolerance of 0-200 bar +/- 5% at +20°C ambient temperature. |
450 ET 450 l/min |
550 ET 550 l/min |
650 ET 650 l/min |
750 ET 750 l/min |
Purification system |
2 Hyperfilters |
|||
Fan cooling airflow |
450 ET 4.050 m 3 /h |
550 ET 4,820 m 3 /h |
650 ET 4,820 m 3 /h |
750 ET 5.590 m 3 /h |
Weight Standard model. Weight and dimensions may vary depending on the accessories. |
450 ET 446kg |
550 ET 451kg |
650 ET 455kg |
750 ET 463kg |
Dimensions (W x D x H) |
93.5 x 130 x 173.5 cm |
Motor
Power |
450 ET 7.5kW |
550 ET 9kW |
650 ET 11kW |
750 ET 15kW |
Engine type |
450 ET Three-phase electric |
550 ET Three-phase electric |
650 ET Three-phase electric |
750 ET Three-phase electric |
Operating voltage Different voltages / frequencies available upon request |
450 ET 400V, 50Hz |
550 ET 400V, 50Hz |
650 ET 400V, 50Hz |
750 ET 400V, 50Hz |
Rated current |
450 ET 13.2A |
550 ET 13.2A |
650 ET 13.2A |
750 ET 13.2A |
Engine revolutions (RPM) |
450 ET 2,870 |
550 ET 2,880 |
650 ET 2,910 |
750 ET 2,920 |
Protection class |
IP55 (TEFC) |